A-1
oxygen sensor
|
C6689-A1
|
Ultra-fast response (90% in less
than 4 seconds) in the percent oxygen
region. |
A-2
oxygen sensor
|
C6689-A2C
|
Used
for trace O2 measurements in CO2
containing backgrounds (0.1-100%
CO2). CO2 must be present. |
A-2CXL
oxygen sensor
|
B74033-A2CXL
|
Specially qualified A2C sensor to
operate in XL model analyzers. Low
range limit is 0-1 ppm. |
A-5
oxygen sensor
|
C6689-A5
|
Intermittent
or continuous monitoring of percent
O2 in gas mixtures containing 0-100%
CO2.90% response is time is 45 seconds. |
B-1
oxygen sensor
|
C6689-B1
|
General purpose percent oxygen analysis
where fast response is desired (90%
in less than 7 seconds). |
B-2C
oxygen sensor
|
C6689-B2C
|
General
purpose trace O2 analysis for use
in inert gas and hydrocarbon streams.
Low range limit is 0-10 ppm. |
INSTA
TRACE
oxygen sensor
|
B71875
|
Special patented construction provides
rapid recovery, during initial cell
installation, to low PPM levels
by reducing the recovery period
from several hours to just minutes.
Low range limit is 0-10 ppm. |
B-2CXL
oxygen sensor
|
C6689-B2CXL
|
Specially
qualified B-2C sensor to operate
in XL model analyzers. Low range
limit is 0-1 ppm. |
B-3
oxygen sensor
|
C6689-B3
|
Percent O2 analysis, best compromise
between long life and fast response. |
B-4C
oxygen sensor
|
C14613-B4C
|
Trace
O2 cell specifically designed for
the Model 317EXI. |
B-5
oxygen sensor
|
C45091-B5
|
Special application cell (non-standard)
where long life and moderately fast
response are required; B-5 has a
factor of 3x the life of a B-3. |
B-5F
oxygen sensor
|
C45091-B5F
|
Special
application cell (non-standard)
where long life and moderately fast
response, in the presence of CO2,
are required. |
B-7
oxygen sensor
|
C45091-B7
|
Special application cell (non-standard)
where fast response is required;
the B-7 has a factor of 3x the life
of a B-1 cell. |
B-7F
oxygen sensor
|
C45091-B7F
|
Special
application cell (non-standard)
where moderate life and fast response,
in the presence of CO2, are required. |
C-1
oxygen sensor
|
C6689-C1
|
Rarely
used. Schematic for reference only. |
C-2
oxygen sensor
|
C6689-C2
|
Rarely
used. Schematic for reference only. |
C-3
oxygen sensor
|
C6689-C3
|
Percent
O2 measurements where maximum cell
life is desired (high O2 applications). |
C-5
oxygen sensor
|
C45091-C5
|
Special
application cell (non-standard)
where long life is required; the
C-5 has a factor of 3x the life
of a C-3 cell. |
C-5F
oxygen sensor
|
C45091-C5F
|
Special
application cell (non-standard)
where long life, in the presence
of CO2, is required. |
C-6
oxygen sensor
|
C54090-C6
|
Motion
insensitive percent O2 measurements
for use in hand held portable monitors. |
E-1
oxygen sensor
|
C14991-E1
|
Special
cell with performance characteristic
of the C-3 with 5x the life. |
E-2
oxygen sensor
|
C57283-E2
|
Long
life cell for use is the Model 3290
(for use in unattended air liquefaction
nitrogen skids). |
F-1R
|
C40371-F1R
|
U0-1000
ppm CO in Ai |
F-3
|
C55194-F3
|
Rarely
used. Schematic for reference only. |
INSTA
TRACE - CO2
|
B73016
|
Special
patented construction provides rapid
recovery, during initial cell installation,
to low PPM levels by reducing the
recovery period from several hours
to just minutes. Used for trace
O2 measurements in CO2 containing
backgrounds (0-100% CO2) in the
3000T analyzer series. |
INSTA
TRACE - XL
oxygen sensor
|
B73592
|
Special
patented construction provides rapid
recovery, during initial cell installation,
to low PPM levels by reducing the
recovery period from several hours
to just minutes. Specially qualified
sensor to operate in XL model analyzers
with a low range limit of 0-1 ppm. |
K-1
oxygen sensor
|
C43832-K1
|
Smallest
Micro-fuel Cell, for use in applications
where small size or multiple sensing
requirements exist. |
L-2C
oxygen sensor
|
C6689-L2C
|
Used
for general purpose trace oxygen
analysis in the 3000T analyzer series. |
L-2CI
oxygen sensor
|
C6689-L2CI
|
Used
in the Model 3000T series for trace
O2 measurements; use only in CO2
and H2 background mixtures (e.g.
inert gas generators). |
S-2C
oxygen sensor
|
C6689-S2C
|
Trace
oxygen cell for use in TurbO2 analyzer.
Provides rapid recovery from air
calibration (approximately 20 minutes). |
Z-2C
oxygen sensor
|
C6689-Z2C
|
Has
the same features as the S-2, except
configured for use in the Model
3190. |